DELL Poweredge R760 12*3.5"Chassis 2u Rack Server 4th/5th Generation CPU - Server-Wiederverkäufer

DELL-SERVER/

DELL Poweredge R760 12*3.5Chassis 2u Rack Server 4th/5th Generation CPU

The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize demanding workloads.

  • Produktdetails
  • transportation
Product Description

PowerEdge R760 rack server

The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize demanding workloads.
DELL Poweredge R760 12*3.5"Chassis 2u Rack Server 4th/5th Generation CPU
DELL Poweredge R760 12*3.5"Chassis 2u Rack Server 4th/5th Generation CPU
Specification
Model no.
DELL PowerEdge R760
Prozessor
• Up to two 4th Generation Intel Xeon Scalable or Intel Xeon Max processors with up to 56 cores per processor and with optional
Intel® QuickAssist Technology

• Up to two 5th Generation Intel Xeon Scalable processors with up to 64 Kerne pro Prozessor
Gedächtnis
• 32 DDR5-DIMM-Steckplätze, unterstützt RDIMM 8 Max. TB,

• Speeds up to 4800 MT/s on the 4th Generation Intel Xeon Scalable or Intel XeonMax processors
• Speeds up to 5600 MT/s on the 5th Generation Intel Xeon Scalable processors
• Supports registered ECC DDR5 DIMMs
only
Speicher-Controller
Interne Steuerungen: PERC H965i, PERC H755, PERC H755N, PERC H355 • External Controller: PERC H965e

• Interner Stiefel: Boot-optimiertes Speichersubsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs oder USB
• SAS HBA (Nicht-RAID-Betrieb): HBA355e, HBA355i, HBA465i
• Software-RAID: Nr. S160
Laufwerksschächte
Einkerker vorne:

•Bis 12 x 3,5-Zoll-SAS/SATA (HDD/SSD) Max 240 TB
•Bis 8 x 2,5-Zoll-SAS/SATA/NVMe (HDD/SSD) Max 122.88 TB
• Up to16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) Max 245.76 TB
•Bis 16 x EDSFF E3. S Gen5 NVMe (SSD) Max 122.88 TB
•Bis 24 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 368.64 TB Rear bays:
•Bis 2 x 2,5-Zoll-SAS/SATA/NVMe (HDD/SSD) Max 30.72 TB
•Bis 4 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 61.44 TB
•Bis 4 x EDSFF E3. S Gen5 NVMe (SSD) Max 30.72 TB
Stromversorgung
3200 W Titan 277 VAC oder 336 HGÜ, Hot-Swap redundant

• 2800 W Titan 200-240 HLAC or 240 HGÜ, Hot-Swap redundant
• 2400 W Platin 100-240 VAC oder 240 HGÜ, Hot-Swap redundant
• 1800 W Titan 200-240 HLAC or 240 HGÜ, Hot-Swap redundant
• 1400 WTitanium 277 VAC oder 336 HGÜ, Hot-Swap redundant
• 1400 W Platin 100-240 VAC oder 240 HGÜ, Hot-Swap redundant
• 1100 W Titanium100-240 VAC or 240 HGÜ, Hot-Swap redundant
• 1100 W -(48-60) VDC, Hot-Swap redundant
• 800 W Platin 100-240 VAC oder 240 HGÜ,Hot-Swap redundant
• 700 W Titan 200-240 HLAC or 240 HGÜ, Hot-Swap redundant
Cooling options
• Air cooling

• Optional Direct Liquid Cooling (DLC)
Anmerkung: DLC is a rack solution and requires rack manifolds and a cooling
distribution unit (CDU) zu betreiben
Eingebettetes Management
• iDRAC9

• iDRAC Direct
• iDRAC RESTful API with Redfish
• iDRAC Service Module
• Quick Sync 2 Funkmodul

Zurück:

Nächster:

Hinterlasse eine Antwort