PowerEdge R760 rack server
The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize demanding workloads.


| Model no. | DELL PowerEdge R760 | 
| Prozessor | • Up to two 4th Generation Intel Xeon Scalable or Intel Xeon Max processors with up to 56 cores per processor and with optional Intel® QuickAssist Technology • Up to two 5th Generation Intel Xeon Scalable processors with up to 64 Kerne pro Prozessor | 
| Gedächtnis | • 32 DDR5-DIMM-Steckplätze, unterstützt RDIMM 8 Max. TB,
 • Speeds up to 4800 MT/s on the 4th Generation Intel Xeon Scalable or Intel XeonMax processors • Speeds up to 5600 MT/s on the 5th Generation Intel Xeon Scalable processors • Supports registered ECC DDR5 DIMMs only | 
| Speicher-Controller |  Interne Steuerungen: PERC H965i, PERC H755, PERC H755N, PERC H355 • External Controller: PERC H965e
 • Interner Stiefel: Boot-optimiertes Speichersubsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs oder USB • SAS HBA (Nicht-RAID-Betrieb): HBA355e, HBA355i, HBA465i • Software-RAID: Nr. S160 | 
| Laufwerksschächte | Einkerker vorne:
 •Bis 12 x 3,5-Zoll-SAS/SATA (HDD/SSD) Max 240 TB •Bis 8 x 2,5-Zoll-SAS/SATA/NVMe (HDD/SSD) Max 122.88 TB • Up to16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) Max 245.76 TB •Bis 16 x EDSFF E3. S Gen5 NVMe (SSD) Max 122.88 TB •Bis 24 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 368.64 TB Rear bays: •Bis 2 x 2,5-Zoll-SAS/SATA/NVMe (HDD/SSD) Max 30.72 TB •Bis 4 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 61.44 TB •Bis 4 x EDSFF E3. S Gen5 NVMe (SSD) Max 30.72 TB | 
| Stromversorgung |  3200 W Titan 277 VAC oder 336 HGÜ, Hot-Swap redundant
 • 2800 W Titan 200-240 HLAC or 240 HGÜ, Hot-Swap redundant • 2400 W Platin 100-240 VAC oder 240 HGÜ, Hot-Swap redundant • 1800 W Titan 200-240 HLAC or 240 HGÜ, Hot-Swap redundant • 1400 WTitanium 277 VAC oder 336 HGÜ, Hot-Swap redundant • 1400 W Platin 100-240 VAC oder 240 HGÜ, Hot-Swap redundant • 1100 W Titanium100-240 VAC or 240 HGÜ, Hot-Swap redundant • 1100 W -(48-60) VDC, Hot-Swap redundant • 800 W Platin 100-240 VAC oder 240 HGÜ,Hot-Swap redundant • 700 W Titan 200-240 HLAC or 240 HGÜ, Hot-Swap redundant | 
| Cooling options | • Air cooling
 • Optional Direct Liquid Cooling (DLC) Anmerkung: DLC is a rack solution and requires rack manifolds and a cooling distribution unit (CDU) zu betreiben | 
| Eingebettetes Management | • iDRAC9
 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 Funkmodul | 
 Server-Wiederverkäufer
		Server-Wiederverkäufer
	 
 
				
















