PowerEdge R760 rack server
The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize demanding workloads.


Model no.
|
DELL PowerEdge R760
|
Processore
|
• Fino a due processori Intel Xeon scalabili o Intel Xeon Max di 4a generazione con un massimo di 56 cores per processor and with optional
Intel® QuickAssist Technology • Fino a due processori scalabili Intel Xeon di 5a generazione con un massimo di 64 Core per processore
|
Memoria
|
• 32 Slot DIMM DDR5, supporta RDIMM 8 TB max,
• Velocità fino a 4800 MT/s on the 4th Generation Intel Xeon Scalable or Intel XeonMax processors
• Velocità fino a 5600 MT/s on the 5th Generation Intel Xeon Scalable processors
• Supports registered ECC DDR5 DIMMs
only |
Controller di archiviazione
|
Internal Controllers: PERC H965i, PERC H755, PERC H755N, PERC H355 • External Controller: PERC H965e
• Stivale interno: Sottosistema di archiviazione ottimizzato per l'avvio (BOSS-N1): HWRAID 2 x SSD M.2 NVMe o USB
• SAS HBA (non RAID): HBA355e, HBA355i, HBA465i
• RAID software: S160
|
Alloggiamenti per unità
|
Alloggiamenti anteriori:
•Fino a 12 x SAS/SATA da 3,5 pollici (HDD/SSD) Max 240 TUBERCOLOSI
•Fino a 8 x SAS/SATA/NVMe da 2,5 pollici (HDD/SSD) Max 122.88 TUBERCOLOSI
• Up to16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) Max 245.76 TUBERCOLOSI
•Fino a 16 x EDSFF E3.S Gen5 NVMe (SSD) Max 122.88 TUBERCOLOSI
•Fino a 24 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 368.64 TB Rear bays:
•Fino a 2 x SAS/SATA/NVMe da 2,5 pollici (HDD/SSD) Max 30.72 TUBERCOLOSI
•Fino a 4 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 61.44 TUBERCOLOSI
•Fino a 4 x EDSFF E3.S Gen5 NVMe (SSD) Max 30.72 TUBERCOLOSI
|
Power supply
|
3200 W Titanium 277 VAC or 336 HVDC, hot swap redundant
• 2800 W Titanium 200-240 HLAC or 240 HVDC, hot swap redundant
• 2400 W Platinum 100-240 VAC or 240 HVDC, hot swap redundant
• 1800 W Titanium 200-240 HLAC or 240 HVDC, hot swap redundant
• 1400 WTitanium 277 VAC or 336 HVDC, hot swap redundant
• 1400 W Platinum 100-240 VAC or 240 HVDC, hot swap redundant
• 1100 W Titanium100-240 VAC or 240 HVDC, hot swap redundant
• 1100 W -(48-60) VDC, hot swap redundant
• 800 W Platinum 100-240 VAC or 240 HVDC,hot swap redundant
• 700 W Titanium 200-240 HLAC or 240 HVDC, hot swap redundant
|
Cooling options
|
• Air cooling
• Optional Direct Liquid Cooling (DLC)
Note: DLC is a rack solution and requires rack manifolds and a cooling
distribution unit (CDU) to operate |
Embedded Management
|
• iDRAC9
• iDRAC Direct
• iDRAC RESTful API with Redfish
• iDRAC Service Module
• Quick Sync 2 wireless module
|