The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize
demanding workloads.

  • Product Details
  • transportation

PowerEdge R760 rack server

The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize
demanding workloads.
Wholesale DELL EMC Poweredge R760 R760xs 8*2.5"Chassis 2u Rack Server
Specification
Model no.
DELL PowerEdge R760
Processor
• Up to two 4th Generation Intel Xeon Scalable or Intel Xeon Max processors with up to 56 cores per processor and with optional
Intel® QuickAssist Technology

• Up to two 5th Generation Intel Xeon Scalable processors with up to 64 cores per processor
Memory
• 32 DDR5 DIMM slots, supports RDIMM 8 TB max,

• Speeds up to 4800 MT/s on the 4th Generation Intel Xeon Scalable or Intel XeonMax processors
• Speeds up to 5600 MT/s on the 5th Generation Intel Xeon Scalable processors
• Supports registered ECC DDR5 DIMMs
only
Storage controllers
 Internal Controllers: PERC H965i, PERC H755, PERC H755N, PERC H355 • External Controller: PERC H965e

• Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs or USB
• SAS HBA (non-RAID): HBA355e, HBA355i, HBA465i
• Software RAID: S160
Drive Bays
Front bays:

• Up to 12 x 3.5-inch SAS/SATA (HDD/SSD) max 240 TB
• Up to 8 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 122.88 TB
• Up to16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 245.76 TB
• Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) max 122.88 TB
• Up to 24 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) max 368.64 TB Rear bays:
• Up to 2 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 30.72 TB
• Up to 4 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) max 61.44 TB
• Up to 4 x EDSFF E3.S Gen5 NVMe (SSD) max 30.72 TB
Power supply
 3200 W Titanium 277 VAC or 336 HVDC, hot swap redundant

• 2800 W Titanium 200-240 HLAC or 240 HVDC, hot swap redundant
• 2400 W Platinum 100-240 VAC or 240 HVDC, hot swap redundant
• 1800 W Titanium 200-240 HLAC or 240 HVDC, hot swap redundant
• 1400 WTitanium 277 VAC or 336 HVDC, hot swap redundant
• 1400 W Platinum 100-240 VAC or 240 HVDC, hot swap redundant
• 1100 W Titanium100-240 VAC or 240 HVDC, hot swap redundant
• 1100 W -(48-60) VDC, hot swap redundant
• 800 W Platinum 100-240 VAC or 240 HVDC,hot swap redundant
• 700 W Titanium 200-240 HLAC or 240 HVDC, hot swap redundant
Cooling options
• Air cooling

• Optional Direct Liquid Cooling (DLC)
Note: DLC is a rack solution and requires rack manifolds and a cooling
distribution unit (CDU) to operate
Embedded Management
• iDRAC9

• iDRAC Direct
• iDRAC RESTful API with Redfish
• iDRAC Service Module
• Quick Sync 2 wireless module