DELL Poweredge R760 12*3.5"Chassis 2u Rack Server 4th/5th Generation CPU - Revendedores de servidores

SERVIDOR DELL/

DELL Poweredge R760 12*3.5Chassis 2u Rack Server 4th/5th Generation CPU

The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize demanding workloads.

  • Detalhes do produto
  • transportation

PowerEdge R760 rack server

The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize demanding workloads.
DELL Poweredge R760 12*3.5"Chassis 2u Rack Server 4th/5th Generation CPU
DELL Poweredge R760 12*3.5"Chassis 2u Rack Server 4th/5th Generation CPU
Specification
Model no.
DELL PowerEdge R760
Processador
• Up to two 4th Generation Intel Xeon Scalable or Intel Xeon Max processors with up to 56 cores per processor and with optional
Intel® QuickAssist Technology

• Up to two 5th Generation Intel Xeon Scalable processors with up to 64 Núcleos por processador
Memória

32 Slots DIMM DDR5, supports RDIMM 8 TB máximo,

• Speeds up to 4800 MT/s on the 4th Generation Intel Xeon Scalable or Intel XeonMax processors
• Speeds up to 5600 MT/s on the 5th Generation Intel Xeon Scalable processors
• Supports registered ECC DDR5 DIMMs
only
Controladores de armazenamento

Controladores internos: PERC H965i, PERC H755, PERC H755N, PERC H355 • External Controller: PERC H965e

• Internal Boot: Subsistema de armazenamento otimizado para inicialização (CHEFE-N1): TRANÇA 2 x M.2 NVMe SSDs or USB
• SAS HBA (não-RAID): HBA355e, HBA355i, HBA465i
• Software RAID: S160
Baias de unidade

Front bays:

• Up to 12 x SAS/SATA de 3,5 polegadas (HDD/SSD) Max 240 TUBERCULOSE
• Up to 8 x SAS/SATA/NVMe de 2,5 polegadas (HDD/SSD) Max 122.88 TUBERCULOSE
• Up to16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) Max 245.76 TUBERCULOSE
• Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) Max 122.88 TUBERCULOSE
• Up to 24 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 368.64 TB Rear bays:
• Up to 2 x SAS/SATA/NVMe de 2,5 polegadas (HDD/SSD) Max 30.72 TUBERCULOSE
• Up to 4 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 61.44 TUBERCULOSE
• Up to 4 x EDSFF E3.S Gen5 NVMe (SSD) Max 30.72 TUBERCULOSE
Power supply

3200 W Titânio 277 VAC or 336 HVDC, hot swap redundant

2800 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant
2400 W Platina 100-240 VAC or 240 HVDC, hot swap redundant
1800 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant
1400 WTitanium 277 VAC or 336 HVDC, hot swap redundant
1400 W Platina 100-240 VAC or 240 HVDC, hot swap redundant
1100 W Titanium100-240 VAC or 240 HVDC, hot swap redundant
1100 W -(48-60) VDC, hot swap redundant
800 W Platina 100-240 VAC or 240 HVDC,hot swap redundant
700 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant
Cooling options

• Air cooling

• Optional Direct Liquid Cooling (DLC)
Nota: DLC is a rack solution and requires rack manifolds and a cooling
distribution unit (CDU) para operar
Embedded Management

• iDRAC9

• iDRAC Direct
• iDRAC RESTful API with Redfish
• iDRAC Service Module
• Quick Sync 2 wireless module

Prev:

Próximo:

Deixar uma resposta