PowerEdge R760 rack server
The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize demanding workloads.


Model no.
|
DELL PowerEdge R760
|
Processador
|
• Up to two 4th Generation Intel Xeon Scalable or Intel Xeon Max processors with up to 56 cores per processor and with optional
Intel® QuickAssist Technology • Up to two 5th Generation Intel Xeon Scalable processors with up to 64 Núcleos por processador
|
Memória
|
• 32 Slots DIMM DDR5, supports RDIMM 8 TB máximo,
• Speeds up to 4800 MT/s on the 4th Generation Intel Xeon Scalable or Intel XeonMax processors
• Speeds up to 5600 MT/s on the 5th Generation Intel Xeon Scalable processors
• Supports registered ECC DDR5 DIMMs
only |
Controladores de armazenamento
|
Controladores internos: PERC H965i, PERC H755, PERC H755N, PERC H355 • External Controller: PERC H965e
• Internal Boot: Subsistema de armazenamento otimizado para inicialização (CHEFE-N1): TRANÇA 2 x M.2 NVMe SSDs or USB
• SAS HBA (não-RAID): HBA355e, HBA355i, HBA465i
• Software RAID: S160
|
Baias de unidade
|
Front bays:
• Up to 12 x SAS/SATA de 3,5 polegadas (HDD/SSD) Max 240 TUBERCULOSE
• Up to 8 x SAS/SATA/NVMe de 2,5 polegadas (HDD/SSD) Max 122.88 TUBERCULOSE
• Up to16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) Max 245.76 TUBERCULOSE
• Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) Max 122.88 TUBERCULOSE
• Up to 24 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 368.64 TB Rear bays:
• Up to 2 x SAS/SATA/NVMe de 2,5 polegadas (HDD/SSD) Max 30.72 TUBERCULOSE
• Up to 4 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 61.44 TUBERCULOSE
• Up to 4 x EDSFF E3.S Gen5 NVMe (SSD) Max 30.72 TUBERCULOSE
|
Power supply
|
3200 W Titânio 277 VAC or 336 HVDC, hot swap redundant
• 2800 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant
• 2400 W Platina 100-240 VAC or 240 HVDC, hot swap redundant
• 1800 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant
• 1400 WTitanium 277 VAC or 336 HVDC, hot swap redundant
• 1400 W Platina 100-240 VAC or 240 HVDC, hot swap redundant
• 1100 W Titanium100-240 VAC or 240 HVDC, hot swap redundant
• 1100 W -(48-60) VDC, hot swap redundant
• 800 W Platina 100-240 VAC or 240 HVDC,hot swap redundant
• 700 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant
|
Cooling options
|
• Air cooling
• Optional Direct Liquid Cooling (DLC)
Nota: DLC is a rack solution and requires rack manifolds and a cooling
distribution unit (CDU) para operar |
Embedded Management
|
• iDRAC9
• iDRAC Direct
• iDRAC RESTful API with Redfish
• iDRAC Service Module
• Quick Sync 2 wireless module
|