PowerEdge R760 rack server
The Dell PowerEdge R760 enables faster time to value by delivering peak compute performance and optimum configurations to optimize demanding workloads.


| Model no. | DELL PowerEdge R760 | 
| Processador | • Up to two 4th Generation Intel Xeon Scalable or Intel Xeon Max processors with up to 56 cores per processor and with optional Intel® QuickAssist Technology • Up to two 5th Generation Intel Xeon Scalable processors with up to 64 Núcleos por processador | 
| Memória | • 32 Slots DIMM DDR5, supports RDIMM 8 TB máximo,
 • Speeds up to 4800 MT/s on the 4th Generation Intel Xeon Scalable or Intel XeonMax processors • Speeds up to 5600 MT/s on the 5th Generation Intel Xeon Scalable processors • Supports registered ECC DDR5 DIMMs only | 
| Controladores de armazenamento |  Controladores internos: PERC H965i, PERC H755, PERC H755N, PERC H355 • External Controller: PERC H965e
 • Internal Boot: Subsistema de armazenamento otimizado para inicialização (CHEFE-N1): TRANÇA 2 x M.2 NVMe SSDs or USB • SAS HBA (não-RAID): HBA355e, HBA355i, HBA465i • Software RAID: S160 | 
| Baias de unidade | Front bays:
 • Up to 12 x SAS/SATA de 3,5 polegadas (HDD/SSD) Max 240 TUBERCULOSE • Up to 8 x SAS/SATA/NVMe de 2,5 polegadas (HDD/SSD) Max 122.88 TUBERCULOSE • Up to16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) Max 245.76 TUBERCULOSE • Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) Max 122.88 TUBERCULOSE • Up to 24 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 368.64 TB Rear bays: • Up to 2 x SAS/SATA/NVMe de 2,5 polegadas (HDD/SSD) Max 30.72 TUBERCULOSE • Up to 4 x 2.5-inchSAS/SATA/NVMe (HDD/SSD) Max 61.44 TUBERCULOSE • Up to 4 x EDSFF E3.S Gen5 NVMe (SSD) Max 30.72 TUBERCULOSE | 
| Power supply |  3200 W Titânio 277 VAC or 336 HVDC, hot swap redundant
 • 2800 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant • 2400 W Platina 100-240 VAC or 240 HVDC, hot swap redundant • 1800 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant • 1400 WTitanium 277 VAC or 336 HVDC, hot swap redundant • 1400 W Platina 100-240 VAC or 240 HVDC, hot swap redundant • 1100 W Titanium100-240 VAC or 240 HVDC, hot swap redundant • 1100 W -(48-60) VDC, hot swap redundant • 800 W Platina 100-240 VAC or 240 HVDC,hot swap redundant • 700 W Titânio 200-240 HLAC or 240 HVDC, hot swap redundant | 
| Cooling options | • Air cooling
 • Optional Direct Liquid Cooling (DLC) Nota: DLC is a rack solution and requires rack manifolds and a cooling distribution unit (CDU) para operar | 
| Embedded Management | • iDRAC9
 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 wireless module | 
 Revendedores de servidores
		Revendedores de servidores
	 
 
				