03050LVP Control Module STL6SPCBB198 for Dorado 6000

Accessories/

03050LVP Huawei STL6SPCBB198 Storage Control Module for Dorado 6000 Enterprise All-Flash Storage

The Huawei 03050LVP (STL6SPCBB198) is a storage control module for the OceanStor Dorado 6000 all-flash system. It carries the array's control plane, front-end host connectivity and back-end disk management, and pairs with a second controller for active-active redundancy.

  • 产品详情
  • FAQ

Huawei 03050LVP Storage Control Module (STL6SPCBB198) for OceanStor Dorado 6000

The 03050LVP Control Module is a replacement storage controller node for the Huawei OceanStor Dorado 6000 all-flash system, supplied under model code STL6SPCBB198. It is the component that runs the array’s control plane, serves host I/O, and manages the back-end flash. When a controller fails and redundancy is lost, this is the module that restores it.

Key Specifications

Item Detail
Huawei Part Number 03050LVP
Model Code STL6SPCBB198
Device Type Storage control module (controller node)
Compatibility OceanStor Dorado 6000
Position Controller slot, controller enclosure
Redundancy Active-active dual-controller configuration
Condition Tested replacement module

What the Control Module Actually Does

Every read and write on the array passes through the control module: it terminates host connections, runs the caching and tiering logic, manages RAID protection, and drives the back-end SSDs. It also reports health, performance, and event data to the management plane. A degraded controller is therefore not a cosmetic fault — it halves your processing headroom and removes the safety net that keeps the array online during maintenance.

Dual-Controller Redundancy: Why One Failure Matters

Dorado 6000 systems normally run two control modules in an active-active pair, each taking half the workload and mirroring cache state to the other. If one fails, the survivor absorbs the full load. The array keeps serving I/O, but with no redundancy, elevated temperatures, and reduced performance — and any second event risks data unavailability. Replacing the failed module promptly is the whole point of the design.

Firmware and Pairing: Read Before You Swap

Controller replacement is not a disk swap. Before ordering or installing, confirm three things: the model code on your existing module matches STL6SPCBB198, the replacement’s firmware level is compatible with the surviving controller, and your service procedure has been reviewed for the specific Dorado 6000 release you run. Mismatched firmware between an active and a replacement controller can prevent the pair from forming properly. If you are unsure, send us a photo of the module label and your current firmware version, and we will confirm fitment before you commit.

Serviceable in a Redundant Configuration

In a healthy dual-controller array, a control module can be replaced following Huawei’s documented service procedure without taking the whole system offline. The surviving controller continues to serve hosts during the swap. Never remove both modules, and always verify cache mirroring has recovered before considering the maintenance closed.

Ideal Applications

  • Replacing a failed controller in a Dorado 6000 array
  • Restoring active-active redundancy after a controller fault
  • On-site spare stock for business-critical all-flash systems
  • Data center refresh and controller upgrade projects

Testing, Warranty and Support

Every module is tested before shipment and matched to OceanStor Dorado 6000 systems. Units ship with our warranty and technical support, and volume pricing is available for spare-parts programs.

Need help confirming compatibility? Read about active-active controller architecture, or shop more OceanStor Dorado controllers and spare parts from our catalog.


Is this a complete control module? Yes. The 03050LVP is a complete storage control module for the Dorado 6000, not a bare board.

Will it work in Dorado 5000 or 18500 systems? This part is specified for the OceanStor Dorado 6000. Contact us with your model before ordering for other arrays.

Do I need to match firmware with the other controller? Yes. The replacement should run a compatible firmware level with the surviving controller. Share your current version and we will confirm before dispatch.

Can I replace it without shutting down the array? In a redundant dual-controller configuration, the module can be replaced following Huawei's service procedure while the surviving controller serves I/O.

Does it come with a warranty? Yes, all units are tested before dispatch and covered by our warranty and support.


上一篇:

下一篇:

在线留言